A USB decoder talks over one COM port, and only one program can hold it at a time. If your old timing program, a serial monitor or an Arduino window still has it open, RaceLyx cannot connect. It is the most common problem when a club switches to RaceLyx.
Before you start
- A USB decoder (I-Lap or LyxBridge) plugged in.
Step by step
- 1
Connection failed
You click Connect and get Connection failed. The red line names the port, and says it is in use by another application.
Under the Connect button: port_owned_by_other_app: COM3 is in use by another application, or the OS denied access. Close any other serial monitor / IDE / terminal holding the port and try again. Another program has the port open.
- 2
Close the other program
Close the old timing program, a serial monitor, or anything else that talks to the decoder. Check the icons by the clock too.
Usually it is the old timing software still running, sometimes only as an icon by the clock. Press Control Shift Escape to open Task Manager, and end it there if it will not close.
- 3
Retry
Back in RaceLyx, click Retry. The card says Connected, and laps come in.
Retry tries the same port again. If it still fails, unplug the decoder, plug it back in, click Refresh ports, pick the port and click Connect.
- 4
Wrong or missing port
Port not found? Click Refresh ports and pick the port the decoder is on now.
port_not_found: COM3 not found on this system. Is the device unplugged? means the decoder is unplugged, or Windows gave it a new number in another USB socket. Device not showing up? helps when no port appears at all.
Tips
- Close the old timing program completely, including its icon by the clock. Task Manager shows whether it is still running.
- Windows can give the decoder a new COM number when you use another USB socket. Use the same socket every week.
- Only I-Lap and LyxBridge use a COM port. EasyLAP connects over USB without one, and Bluetooth decoders have no port.
- Once the port is free, a decoder you used before connects from Saved Devices in one click.
Troubleshooting
- port_owned_by_other_app: COM3 is in use by another application, or the OS denied access.
- Close the program holding COM3, then click Retry. If nothing else is open, unplug the decoder, plug it back in and try again. Restart the PC if it still fails.
- port_owned_by_this_app: COM3 is already connected in RaceLyx
- RaceLyx already has this port. Find the decoder under Connected on Timing Hardware, and disconnect it first if you want to connect it again.
- port_not_found: COM3 not found on this system. Is the device unplugged?
- Check the cable, click Refresh ports and pick the port the decoder has now.
- No COM port appears.
- Install the USB driver for your cable: open Device not showing up? on Timing Hardware.
Related guides
Something here does not match what you see? Tell us and we will fix the guide.